Performance of (Q)SAR Models in Regulatory Assessments
The retrospective study by Mazoudji et al. (2026) evaluated (Q)SAR model performance using experimental data collected from Austrian, French, and European pharmaceutical scientific advice and authorization procedures. These data provide an opportunity to assess model performance on chemical structures encountered in regulatory practice.¹
The study found that Ames mutagenicity models generally performed better than models for other genotoxicity endpoints. The Leadscope Expert Rules-based model achieved the highest Matthews correlation coefficient (MCC) among the individual Ames models evaluated (0.59), with balanced accuracy of 0.85, sensitivity of 0.79, and specificity of 0.91. The Leadscope statistical model also demonstrated strong predictive performance, with an MCC of 0.46 and balanced accuracy of 0.79. The Leadscope consensus approach achieved an MCC of 0.46 and balanced accuracy of 0.81.¹
These findings provide further evidence of the predictive performance of Leadscope’s complementary expert rule-based and statistical methodologies for bacterial mutagenicity assessment, consistent with the approach recommended under ICH M7.³
Building on Established Methodologies
Earlier research involving FDA/CDER and Leadscope contributed to the development of bacterial mutagenicity models for pharmaceutical applications. In 2019, Landry et al. reported the evaluation of composite statistical models using 388 proprietary pharmaceutical impurities, with negative predictivity ranging from 91% to 95% and approximately 96% chemical coverage.² The study by Mazoudji et al. (2026) provides further evidence supporting the predictive performance of established (Q)SAR methodologies.
What Should the Next Decade Bring?
The findings reinforce the value of computational methodologies currently used for bacterial mutagenicity assessment under ICH M7, while highlighting areas where predictions warrant closer scrutiny. Continued model development remains valuable, particularly for challenging chemical classes such as N-nitrosamines. There are also opportunities to improve how predictions are interpreted and applied in regulatory assessments.
Expert review remains an important component of ICH M7 assessments, particularly when models produce conflicting predictions, compounds fall outside the applicability domain, or additional experimental evidence is available.³
Applying clear and consistent criteria for evaluating prediction reliability, documenting expert reasoning, and communicating uncertainty could strengthen the scientific justification provided in regulatory submissions.
After more than a decade of ICH M7 implementation, the opportunity is to build on established predictive capabilities and further strengthen the consistency of expert review in (Q)SAR assessments.
参考文献
- Mazoudji, A., et al. (2026). Retrospective (Q)SAR analysis of genotoxicity data from European pharmaceutical scientific advice and authorization procedures and performance improvements using structural alert and chemical subspace analyses, reliability filtering, and expert review. Regulatory Toxicology and Pharmacology, Article 106279. https://doi.org/10.1016/j.yrtph.2026.106279
- Landry, C., et al. (2019). Transitioning to composite bacterial mutagenicity models in ICH M7 (Q)SAR analyses. Regulatory Toxicology and Pharmacology, 109, Article 104488.https://doi.org/10.1016/j.yrtph.2019.104488
- International Council for Harmonisation (ICH). (2023). ICH M7(R2): Assessment and control of DNA reactive (mutagenic) impurities in pharmaceuticals to limit potential carcinogenic risk.https://www.fda.gov/media/170461/download